The software that runs the test.

Now in development. One program controls the bench, records every channel on one time base, checks that conditions stay valid, calculates the results exactly as the standard prescribes and writes the report. Your staff run the test; the software keeps the method honest.

One time base for every channel Four synchronised channels over one dishwasher programme: supply voltage within its tolerance band, power with two heating phases, water flow during fills, and inlet water temperature. Vertical markers show programme start, fills, heating, a detected softener regeneration, end of programme and the point where all activity ceases. Supply voltage V Power W Water flow L/min Inlet water °C ±1 % band 15.1 °C Start Heating Regeneration Programme end All activity ceased 0 30 60 90 120 150 180 210 240 min
Every channel shares one clock. Events are marked automatically, so a regeneration cycle or the moment all activity ceases is found from the data, not from someone’s notes. Illustration.

From set-up to report

The software follows the test the way the standard does, step by step.

  1. Prepare

    Checks that every instrument is calibrated and in date, records consumable batches and verifies the load.

  2. Run

    Controls the supply and outlets, starts logging and marks each event on the timeline.

  3. Watch

    Monitors supply, room and water against their tolerances and flags any run that leaves them.

  4. Evaluate

    Applies the calculation rules of the standard to the whole series and evaluates uncertainty.

  5. Report

    Produces the test record and the report, ready for review and release by the laboratory.

What it does

Each function exists because the standard or ISO/IEC 17025 asks for it.

Control

Equipment control

Sets voltage and frequency on the AC source, switches the outlets for test and reference machines, configures the power analyser and data acquisition, and starts and stops integration — from one screen.

One time base

Every parameter on one timeline

Voltage, frequency, THD, power, energy, water flow and volume, inlet, room and in-machine temperatures are logged with a common timestamp. Any moment of a run can be replayed across all channels.

§8.3.1 · Annex K

Event markers and cut-offs

Programme start and end, fills, heating phases, the point where all activity ceases and transitions between low-power modes are detected and marked automatically, with the criterion that triggered each marker.

§5

Validity monitoring

Supply, room climate, water temperature and pressure are compared with their tolerances in real time. A deviation raises an alarm and the affected run is flagged, so invalid data never slips into a result.

§8 · Annexes K, U

Calculations to the standard

Energy, water and programme time per run and per series, hot-water energy from volume-weighted temperature, the rules for excluding regeneration runs and their limits, low-power mode values with stability checks.

Uncertainty

Measurement uncertainty

An uncertainty budget built from the calibration data of the instruments actually used, combined for each reported value. No copy-paste from a spreadsheet template.

ISO/IEC 17025 §6.4

Equipment register

Keeps calibration certificates, due dates, intermediate checks and corrections for every instrument. An instrument that is out of date or failed its last check cannot be selected for a test.

§6.2 · §6.6

Load verification

Guides the operator through the loading plan, records item weights and positions, and stores a photo of the loaded racks with the run. The load is checked before the programme is allowed to start.

§5.7 – §5.9

Consumables and reference machine

Records detergent, rinse aid and salt batches, soil preparation times and reference machine checks, and warns when a time window or a batch rule is about to be broken.

ISO/IEC 17025 §7.5 · §7.8

Test record and report

Raw data, conditions, events, deviations and calculations form the technical record. The report is generated from it in a defined layout, with every value traceable back to the data.

ISO/IEC 17025 §7.11

Data integrity

Raw data is never overwritten. Every edit, exclusion or re-calculation is logged with user, time and reason. Data is saved continuously, so an interruption does not cost the run.

ISO/IEC 17025 §6.2

Users and authorisations

Operators, reviewers and approvers have separate roles. Only staff authorised for the method can run it, and only an approver can release a report.

Built to be assessed

Laboratory software has to be validated before use. Ours is designed with the assessor in mind.

ISO/IEC 17025What the software provides
§6.4 EquipmentRegister with calibration status; out-of-date instruments are blocked
§7.5 Technical recordsComplete record of each run: raw data, conditions, events, operator
§7.6 UncertaintyBudget from the calibration data of the instruments used
§7.7 Validity of resultsReal-time tolerance checks, flagged runs, trend of reference machine results
§7.8 ReportingReport generated from the record in a defined layout
§7.11 Control of dataAudit trail, user roles, protected raw data; validation records delivered with the software

One platform, more standards

IEC 60436 is the first module. Because control, logging and records are shared, modules for other appliance standards — starting with standby power to IEC 62301 — add calculation rules and report layouts, not a new program. Raw data and reports export to CSV, Excel and PDF, and can be passed to your LIMS.

See the software

Ask for a demo with data from a complete test series.